Search Result :

Search Result: All Server Barebones

 

Server Barebones

Model  / SKU Segment #Storage Bay PSU Others Rackmount 
TN200B7108-X4L / B7108T200X4-220PV3HR   Data Center12 LFF1+1 RPSU3 LFF per sled; 2 M.2 per sled; SAS / SATA backplane2U4N
TN200B7108-X4S / B7108T200X4-220PE6HR   Data Center24 SFF1+1 RPSU6 SFF per sled; 2 M.2 per sled; NVMe / SATA backplane2U4N
FT48TB7105 / B7105F48TV8HR-2T-G   New!  GPGPU8 LFF1+1 RPSU12 DIMM; 5 GPU; 2 10 GbE; 3 FANTower
FT48TB7105 / B7105F48TV4HR-2T-G   GPGPU4 LFF1+1 RPSU12 DIMM; 5 GPU; 2 10 GbE; 3 FANTower
FT48TB7105 / B7105F48TV4HR-2T-N   GPGPU4 LFF1+1 RPSU12 DIMM; 5 GPU; 2 10 GbE; 6 FANTower
GT75BB7102 / B7102G75BV6E4HR-2T-HE   New!  Data Center10 SFF(1+1) 800W RPSU 80+ TitaniumUp to 4 NVMe U.2; 24 DIMM; 2 10GbE; 2 M.21U
GT75BB7102 / B7102G75BV10HR-2T-HE   New!  Data Center10 SFF(1+1) 800W RPSU 80+ Titanium24 DIMM; 2 10GbE; 2 M.21U
GA88B8021 / B8021G88V2HR-2T-N   New!  GPGPU2 SFF1+1 RPSUSingle Root Complex; 4 GPU; 2 10GbE1U
GT86CB5630 / B5630G86CV12   Server Storage12 LFF + 2 SFF1 PSU12 data + 2 boot drives1U
GT86CB5630 / B5630G86CV12R   Server Storage12 LFF1 PSU12 data drives1U
GT62FB8026 / B8026G62FV10HR-LE   Server Storage10 SFF1+1 RPSUUp to 10 SATA; 16 DIMM; 2 GbE1U
GT62FB8026 / B8026G62FE10HR   Server Storage10 SFF1+1 RPSUUp to 10 NVMe U.2; 16 DIMM; 2 GbE1U
GT62FB5630 / B5630G62FV6E4HR   Server Storage10 SFF1+1 RPSUUp to 4 NVMe U.2; 12 DIMM1U
GT62FB5630 / B5630G62FV2E8HR   Server Storage10 SFF1+1 RPSUUp to 8 NVMe U.2; 12 DIMM1U
GT62FB5630 / B5630G62FV10HR   Server Storage10 SFF1+1 RPSU12 DIMM; 10 SATA1U
GA88B5631 / B5631G88V2HR-2T-N   GPGPU2 SFF1+1 RPSU12 DIMM; 4 GPU; 2 10GbE; 2 M.21U
GT24EB7106 / B7106G24EV2E2HR   Data Center4 LFF + 2 SFF1+1 RPSUUp to 2 NVMe U.2; 16 DIMM; 2 GbE; 1 M.21U
GT24EB7106 / B7106G24EV4HR   Data Center4 LFF + 2 SFF1+1 RPSU16 DIMM; 2 GbE; 1 M.21U
GT75BB7102 / B7102G75BV10HR-2T   Data Center10 SFF(1+1) 750W RPSU 80+ Platinum24 DIMM; 2 10GbE; 2 M.21U
GT75BB7102 / B7102G75BV6E4HR-2T   Data Center10 SFF(1+1) 750W RPSU 80+ PlatinumUp to 4 NVMe U.2; 24 DIMM; 2 10GbE; 2 M.21U
GT24BB5542 / B5542G24BV4HR   Data Center4 LFF1+1 RPSU4 DIMM; 2 GbE1U
GT62BB5539 / B5539G62BV6E4H-D41 (BTO)   Embedded10 SFF1 PSUXeon D-1541; 2 GbE; Single PSU1U
GT62BB5539 / B5539G62BV6E4H-D41-2T (BTO)   Embedded10 SFF1 PSUXeon D-1541; 2 GbE; RPSU1U
GT62BB5539 / B5539G62BV6E4HR-D41 (BTO)   Embedded10 SFF1+1 RPSUXeon D-1541; 2 10GbE + 2 GBE; Single PSU1U
GT62BB5539 / B5539G62BV6E4HR-D41-2T (BTO)   Embedded10 SFF1+1 RPSUXeon D-1541; 2 10GbE + 2 GbE; RPSU1U
GT86AB7083 / B7083G86AV8   Server Storage8 LFF + 1 SFF1 PSU8 data + 1 boot drives1U
GT86AB7083 / B7083G86AV12-HE   Server Storage12 LFF + 1 SFF1 PSU12 data + 1 boot drives1U
GT62BB7076 / B7076G62BV6E4HR   Data Center10 SFF1+1 RPSUUp to 4 NVMe U.2; 16 DIMM; 2 GbE1U
GT62BB7076 / B7076G62BV10HR   Data Center10 SFF1+1 RPSU16 DIMM; 2 GbE1U
GA80B7081 / B7081G80V4HR-N   GPGPU4 SFF1+1 RPSUDual Root Complex; 3 GPU; 2 GbE1U
GA80B7081 / B7081G80V4HR-2T-N   GPGPU4 SFF1+1 RPSUDual Root Complex; 3 GPU; 2 10GbE1U
GT24BB7076 / B7076G24BV4H   Data Center4 LFF1 PSU16 DIMM; 2 GbE1U
GT24BB7076 / B7076G24BV4HR   Data Center4 LFF1+1 RPSU16 DIMM; 2 GbE1U
GT62BB7076 / B7076G62BV10H   Data Center10 SFF1 PSU16 DIMM; 2 GbE1U
GT24B8226 / B8226G24V4H   Data Center4 LFF1 PSU12 DIMM; 3 GbE1U
YR190B8208 / B8208Y190X2-045V4H [BTO]   Data Center16 SFF1 PSU4 SFF per sled; SAS / SATA backplane1U
TN70AB7106 / B7106T70AU24V2HR   New!  Server Storage26 SFF1+1 RPSUUp to 24 SAS 12G; 16 DIMM; 2 GbE; 1 M.22U
TN70AB7106 / B7106T70AV26HR   New!  Server Storage26 SFF1+1 RPSUUp to 26 SATA 6G; 16 DIMM; 2 GbE; 1 M.22U
TN70AB8026 / B8026T70AV8E16HR   New!  Server Storage24 SFF1+1 RPSUUp to 16 NVMe U.2; 16 DIMM2U
TN76B7102 / B7102T76V8E4HR-2T-N   New!  Server Storage8 LFF + 4 SFF1+1 RPSU24 DIMM; 2 GPU; 2 10 GbE; 4 PCIe x8; 2 M.22U
TN70EB8026 / B8026T70EV10E4HR   New!  Server Storage12 LFF+2 SFF1+1 RPSUUp to 4 NVMe; 16 DIMM; 1 GbE; 2 M.22U
TN70AB8026 / B8026T70AV18E8HR   New!  Server Storage26 SFF1+1 RPSUUp to 8 NVMe U.2; 16 DIMM2U
TN70AB8026 / B8026T70AV2E24HR   New!  Server Storage26 SFF1+1 RPSUUp to 24 NVMe U.2; 16 DIMM2U
TN70AB8026 / B8026T70AV26HR-LE   New!  Server Storage26 SFF1+1 RPSUUp to 26 SATA; 16 DIMM2U
TN76B7102 / B7102T76V12HR-2T-G   Server Storage12 LFF1+1 RPSU24 DIMM; 2 GPU; 2 10 GbE; 2 PCIe x8; 2 M.22U
TN70AB8026 / B8026T70AV16E8HR   Server Storage24 SFF1+1 RPSUUp to 8 NVMe U.2; 16 DIMM2U
TN70AB8026 / B8026T70AE24HR   Server Storage24 SFF1+1 RPSUUp to 24 NVMe U.2; 16 DIMM2U
TN70EB7106 / B7106T70EV12HR   Server Storage12 LFF + 2 SFF1+1 RPSU16 DIMM; 2 GbE; 1 M.22U
TN70EB7106 / B7106T70EV8E4HR   Server Storage12 LFF + 2 SFF1+1 RPSUUp to 4 NVMe U.2; 16 DIMM; 2 GbE; 1 M.22U
TN76B7102 / B7102T76V12HR-2T-N   Server Storage12 LFF1+1 RPSU24 DIMM; 2 GPU; 2 10 GbE; 4 PCIe x8; 2 M.22U
TN70BB7086 / B7086T70BV12HR   Server Storage12 LFF + 2 SFF1+1 RPSU16 DIMM; 3 GbE2U
TN70BB7086 / B7086T70BV8E4HR   Server Storage12 LFF + 2 SFF1+1 RPSUUp to 4 NVMe U.2; 16 DIMM; 3 GbE2U
GN70B7086 / B7086G70V8HR   Data Center8 LFF1+1 RPSU16 DIMM; 3 GbE2U
GN70B7086 / B7086G70V6E2HR   Data Center8 LFF1+1 RPSUUp to 2 NVMe U.2; 16 DIMM; 3 GbE2U
TA80B7071 / B7071T80V8HR-2T-N   GPGPU8 SFF + 2 SFF1+1 RPSUDual Root Complex; 4 GPU; 2 10GbE2U
TA80B7071 / B7071T80V8HR-N   GPGPU8 SFF + 2 SFF1+1 RPSUDual Root Complex; 4 GPU; 2 GbE2U
TA70B8237 / B8237T70V24HR   Data Center24 SFF + 2 SFF1+1 RPSU24 DIMM; 1 GbE2U
FT77DB7109 / B7109F77DV4HR-8X-2T-F   New!  HPC4 LFF2+1 RPSU24 DIMM; 2 10 GbE; SKL-F4U
FT77DB7109 / B7109F77DV10E4HR-8X-2T-F   New!  HPC14 SFF2+1 RPSUUp to 4 NVMe U.2; 24 DIMM; 2 10 GbE4U
FT77DB7109 / B7109F77DV14HR-8X-2T-F   New!  HPC14 SFF2+1 RPSU24 DIMM; 2 10 GbE; SKL-F4U
FA77B7119 / B7119F77V4HR-2T-N   GPGPU4 LFF3+1 RPSU24 DIMM; 10 GPU; 2 10GbE4U
FA77B7119 / B7119F77V10E4HR-2T-N   GPGPU14 SFF3+1 RPSUUp to 4 NVMe U.2; 24 DIMM; 10 GPU; 2 10GbE4U
FA100B7118 / B7118F100V100HR   Server Storage100 LFF1+1 RPSUFront-serviced sled; 1 PCIe x16; OCP 2.0 Mezz.; 1 M.24U
FA77B7119 / B7119F77V14HR-2T-N   GPGPU14 SFF3+1 RPSU24 DIMM; 10 GPU; 2 10GbE4U
FT77DB7109 / B7109F77DV4HR-2T-NF   GPGPU4 LFF2+1 RPSU24 DIMM; 8 GPU; 2 10 GbE; SKL-F4U
FT77DB7109 / B7109F77DV10E4HR-2T-NF   New!  GPGPU14 SFF2+1 RPSUUp to 4 NVMe U.2; 24 DIMM; 8 GPU; 2 10 GbE4U
FT77DB7109 / B7109F77DV14HR-2T-NF   GPGPU14 SFF2+1 RPSU24 DIMM; 8 GPU; 2 10 GbE; SKL-F4U
FT77DB7109 / B7109F77DV14HR-2T-N   GPGPU14 SFF2+1 RPSUUp to 4 NVMe U.2; 24 DIMM; 8 GPU; 2 10 GbE4U
FT77DB7109 / B7109F77DV10E4HR-2T-N   GPGPU14 SFF2+1 RPSUUp to 4 NVMe U.2; 24 DIMM; 8 GPU; 2 10 GbE4U
FT48BB7100 / B7100F48BV10HR-N   GPGPU10 SFF1+1 RPSU12 DIMM; 4 GPU; 2 GbE; 2 M.24U
FT48AB7070 / B7070F48AW16HR   Server Storage8 LFF + 8 SFF2+1 RPSU16 DIMM; 2 GbE; onboard SAS 12G IOC4U
FT76B7922 / B7922F76U8HR-4T (BTO)   HPC8 SFF3+1 RPSU11 PCIe x8; 4 10GbE4U
FT76B7922 / B7922F76U8HR-2T (BTO)   HPC8 SFF3+1 RPSU11 PCIe x8; 2 10GbE4U
FT76B7922 / B7922F76U8HR-4T-HE-X (BTO)   GPGPU8 SFF3+1 RPSUQuad Root Complex; 4 GPU; 4 10GbE4U
FT48AB7070 / B7070F48AV4HR-N   GPGPU4 LFF2+1 RPSUDual Root Complex; 3 GPU; 2 GbE4U
FT48AB7070 / B7070F48AV16HR   Server Storage8 LFF + 8 SFF2+1 RPSU16 DIMM; 2 GbE4U
FT77CB7079 / B7079F77CV10HR-N   GPGPU10 LFF2+1 RPSUDual Root Complex; 8 GPU; 2 GbE4U
FT77CB7079 / B7079F77CV10HR-2T-N (BTO)   GPGPU10 LFF2+1 RPSUDual Root Complex; 8 GPU; 2 10GbE4U